The SDS is a training document. Use it to answer these employee questions:
Annual refresher: Review Sections 4, 6, and 8 in toolbox talks. Simulate an eye wash station drill.
Mandatory for:
Skip if you are: An end-user just near a treated cooling tower (very low risk at ppm levels), but you still need access to the SDS per OSHA’s Hazard Communication Standard.
Bottom line: Nalco 2593 is a well-formulated scale/corrosion inhibitor, but the concentrate is acidic and an eye hazard. Treat it with respect – nitrile gloves + goggles – and don’t dump it down the drain. The SDS is accurate and thorough for its category, though the proprietary nature hides exact polymer details.
Nalco 2593 (often associated with microbiocides for industrial water systems) is a hazardous chemical that requires careful handling. While Nalco Water SDS are typically not available for direct public download and must be requested through the Ecolab SDS Portal, the following guide outlines the critical safety data based on standard Nalco 2593 documentation. 1. Hazard Identification
Nalco 2593 is primarily classified as corrosive and hazardous to both humans and the environment.
Physical Hazards: Low fire hazard, but it may burn if heated above its flash point ( Health Hazards:
Skin/Eyes: Can cause severe irritation or tissue damage upon contact.
Inhalation: Vapors are toxic and can cause headaches, nausea, or dizziness.
Ingestion: Harmful or fatal if swallowed; can cause central nervous system depression. 2. Personal Protective Equipment (PPE)
Due to its corrosive nature, strict PPE is required during handling:
Eye Protection: Wear chemical splash goggles and a full-face shield.
Skin Protection: Use impervious gloves (nitrile or neoprene), chemical-resistant boots, and a chemical-resistant apron.
Respiratory: Not typically needed with good ventilation, but use an approved organic vapor respirator if mists or aerosols are generated. 3. First Aid Measures
Eye Contact: Immediately flush with water for at least 15 minutes and seek medical attention.
Skin Contact: Remove contaminated clothing and wash the affected area with plenty of water for 15 minutes.
Inhalation: Move the person to fresh air. Treat symptomatically and seek medical advice.
Ingestion: Do not induce vomiting. Wash out the mouth with water and seek immediate medical help. 4. Handling & Storage
Storage: Keep in a cool, well-ventilated area. Ensure containers are tightly closed when not in use.
Incompatibilities: Avoid contact with reactive metals like aluminum, as this can generate flammable hydrogen gas. Avoid high temperatures and open flames.
Disposal: The product is toxic to aquatic life; do not release it into the environment. Dispose of it in accordance with local and federal regulations. 5. Obtaining the Full SDS
To ensure you have the most up-to-date version (standardized into the 16-section Globally Harmonized System format), you should: Visit the Ecolab/Nalco Water SDS Request Form.
Provide your specific product name (Nalco 2593) and your location.
Check your purchase invoice or product label for a specific part number to speed up the search.
Isothiazolinone Microbiocide Safety Guide | PDF | Waste - Scribd nalco 2593 msds
NALCO 2593 is a specialized non-oxidizing microbiocide (often classified as an isothiazolinone-based formula) primarily used to control the growth of bacteria, fungi, and algae in industrial water systems. It is frequently applied in industrial cooling towers, boilers, and air-wash systems. Key Hazard Identifications
According to safety documentation, Nalco 2593 is considered a hazardous substance:
Physical Hazards: It is described as a combustible liquid; keep it away from heat and open flames. Health Hazards:
Skin/Eyes: It is corrosive and causes moderate to severe irritation or burns upon contact.
Inhalation: Prolonged inhalation of vapors may be harmful and can cause central nervous system depression or nausea.
Sensitization: May cause an allergic skin reaction (sensitization) with repeated exposure.
Environmental Hazards: It is harmful to aquatic life with long-lasting effects. Safe Handling & Personal Protective Equipment (PPE)
Due to its corrosive nature, strict safety protocols are required during handling:
Hand Protection: Wear chemical-resistant gloves (e.g., PVC, neoprene, or nitrile).
Eye Protection: Use chemical splash goggles and a full face shield.
Body Protection: Wear standard protective clothing to prevent skin contact.
Ventilation: Use only in well-ventilated areas to avoid breathing vapors or mists.
Hygiene: Wash hands thoroughly after handling. An eye wash station and safety shower should be available in the immediate work area. Storage & Disposal
Storage: Keep containers tightly closed in a cool, dry, and well-ventilated place. Store separately from strong oxidizers (e.g., chlorine, peroxides) to avoid dangerous reactions.
Disposal: This product may meet the criteria for hazardous waste under RCRA regulations. It must be disposed of at a licensed hazardous waste facility; do not discharge into sewer systems without local authority approval. First Aid Measures
Eye Contact: Immediately flush eyes with plenty of water for at least 15 minutes and seek medical attention.
Skin Contact: Wash affected areas with plenty of water and soap. Remove and launder contaminated clothing before reuse.
Ingestion: Rinse mouth with water. Do not induce vomiting unless directed by medical personnel. Call a poison center immediately.
For the most current version of this document, you can request an official Safety Data Sheet (SDS) directly through the Ecolab/Nalco Water SDS Request Form.
Do you need guidance on calculating the specific dosage or application frequency for a particular cooling tower or boiler system?
Isothiazolinone Microbiocide Safety Guide | PDF | Waste - Scribd
Nalco 2593 is a specialized non-oxidizing microbiocide primarily used to control bacteria, algae, and fungi in industrial water systems. Because it is classified as a hazardous chemical, having the Material Safety Data Sheet (MSDS)—now more commonly referred to as the Safety Data Sheet (SDS)—is essential for safe handling and regulatory compliance. What is Nalco 2593?
Nalco 2593 is a liquid biocide formulation designed for industrial cooling towers, closed-loop cooling systems, and air washers. It is often used in food processing facilities for treating boilers and steam lines, provided that the steam or treated water does not come into direct contact with edible products. Chemical Family: Isothiazolinone.
Active Ingredients: Typically contains 5-chloro-2-methyl-4-isothiazolin-3-one and 2-methyl-4-isothiazolin-3-one. Physical State: Liquid. Key Sections of the Nalco 2593 MSDS/SDS
An MSDS provides critical information across several sections to ensure workplace safety. For Nalco 2593, the following sections are of particular importance: 1. Hazard Identification Nalco 2593 is classified as a corrosive material. The SDS is a training document
Health Hazards: It can cause severe skin burns and permanent eye damage. It is also a known skin sensitizer, meaning repeated exposure can lead to allergic reactions.
Environmental Hazards: As a biocide, it is highly toxic to aquatic life and must be prevented from entering natural waterways. 2. First Aid Measures In the event of exposure, immediate action is required:
Eye Contact: Rinse immediately with plenty of water for at least 15 minutes, holding eyelids open. Seek urgent medical attention.
Skin Contact: Remove contaminated clothing and wash the skin thoroughly with soap and water.
Ingestion: Do not induce vomiting. Rinse the mouth with water and contact a poison control center immediately. 3. Handling and Storage
Isothiazolinone Microbiocide Safety Guide | PDF | Waste - Scribd
The NALCO 2593 MSDS is not a one-time download to be filed away. It is a dynamic risk communication tool. As you scale water treatment operations, change injection points, or train new personnel, revisit the SDS. It answers not just “Is this dangerous?” but “How dangerous, under what conditions, and with what controls?”
Remember: No summary, including this article, replaces the official document. Always keep the most current NALCO 2593 SDS in your central safety repository, at your loading dock, and accessible to your emergency response team.
Disclaimer: This article is for informational purposes only and does not constitute professional safety or legal advice. Product formulations change; always refer to the latest SDS provided by NALCO Water / Ecolab for specific regulatory and safety information.
Need the official document?
Visit Ecolab.com → SDS Search → Enter “2593”. Or call 1-800-352-5326.
NALCO 2593 is a microbiocide (algaecide/slimicide) used primarily for controlling bacteria, fungi, and algae in industrial water systems. It is considered
and can cause moderate to severe irritation or damage to the eyes and skin. Acute Effects:
Inhalation of high concentrations may lead to nausea, dizziness, or central nervous system depression. Environmental Impact:
The product is hazardous to the environment and aquatic life. Protective Gear:
Required PPE typically includes impermeable gloves (neoprene, nitrile, or PVC) and eye protection. How to Get the Official SDS/MSDS Nalco Water (an
company) does not always provide these documents via public direct download. To ensure you have the most up-to-date version for your specific region, use one of the following methods: Request Online: Nalco Water SDS Request Form to have the document emailed to you. SDS Search Portal: You can search by product name or code on the Ecolab SDS Search Customer Service: Nalco Water Customer Service +1-800-288-0879 Emergency Contact: For chemical emergencies (spills or exposures), call +1-800-424-9300 (24 hours). Usage Limitations
Isothiazolinone Microbiocide Safety Guide | PDF | Waste - Scribd
NALCO® 2593 is a hazardous, isothiazolinone-based microbiocide used primarily as an algaecide, slimicide, and disinfectant in industrial water systems. Due to its corrosive nature and toxicity, Safety Data Sheets (SDS) are strictly required for handling, though they are typically provided by Ecolab directly upon purchase rather than being hosted for general public download. Product Summary and Usage
Primary Function: Controls bacteria, fungi, and algae in industrial wastewater treatment, sewage systems, and cooling water systems (e.g., condensers and air washers).
Industrial Applications: It is certified by NSF International (Category G7) for treating boilers and cooling systems in food processing areas, provided the treated water or steam does not contact edible products.
Chemical Nature: Liquid formulation containing active ingredients like 5-chloro-2-methyl-4-isothiazolin-3-one and 2-methyl-4-isothiazolin-3-one. Key Hazard Identifications
Based on safety data for this and similar Nalco biocides, the following risks are associated with NALCO 2593: Safety Data Sheets - SDS - MSDS - Ecolab
IMPORTANT DISCLAIMER: SAFETY DATA SHEETS (SDS) AND PRODUCT FORMULATIONS CHANGE. The information below is a detailed report based on the most commonly available historical data for Nalco 2593. However, Nalco (now Ecolab) frequently updates formulations and documentation. For compliance with OSHA, WHMIS, or other regulatory bodies, you must obtain the official, current Safety Data Sheet (SDS) directly from Ecolab/Nalco or your supplier.
The MSDS for NALCO 2593 clearly identifies this product as a corrosive, acidic scale inhibitor that demands respect and rigorous handling procedures. While highly effective in controlling scale in industrial cooling systems, its potential to cause severe eye and skin damage, along with moderate aquatic toxicity, requires facilities to implement:
Always consult the actual NALCO 2593 Safety Data Sheet provided by Nalco Water — not an archived or third-party copy — before handling, storing, or disposing of this chemical. Compliance with OSHA’s HazCom Standard (29 CFR 1910.1200) requires that your specific MSDS be accessible, legible, and less than 5 years old. Annual refresher: Review Sections 4, 6, and 8
For the most current NALCO 2593 MSDS:
Visit https://www.ecolab.com → Click “SDS Search” → Enter “NALCO 2593” → Download PDF.
This article is for informational and compliance guidance purposes only. Always follow the exact recommendations on the official MSDS/SDS provided by the manufacturer.
Nalco 2593 is a highly corrosive microbiocide primarily used to control bacteria, algae, and fungi in industrial water systems. Due to its chemical potency, handling this substance requires strict adherence to safety protocols to prevent severe skin burns and eye damage. Product Overview Primary Function : Industrial microbiocide and preservative. Active Ingredients : Typically contains a mixture of 5-Chloro-2-methyl-4-isothiazolin-3-one 2-Methyl-4-isothiazolin-3-one (often referred to as CMIT/MIT). Applications
: Used in cooling water systems, air washer systems, and papermill process water. Hazard Identification According to safety documentation available on , the product carries the following risks: Corrosivity
: Causes severe skin burns and permanent eye damage upon contact. Sensitization : May cause an allergic skin reaction (skin sensitizer). : Harmful if swallowed or inhaled in high concentrations. Environmental Impact : Highly toxic to aquatic life with long-lasting effects. Safety & First Aid Measures
If you are handling this chemical, refer to the full technical details which can often be found in repositories like Google Drive for specific SDS (Safety Data Sheet) versions. Requirement / Action Personal Protective Equipment (PPE)
Wear chemical-resistant gloves (nitrile or butyl), safety goggles, a face shield, and protective clothing. Eye Contact
Rinse immediately with plenty of water for at least 15 minutes and seek urgent medical attention. Skin Contact
Remove contaminated clothing and wash skin with soap and water immediately.
Store in a cool, well-ventilated area away from incompatible materials like strong oxidizing agents. Spill Response Containment
: Block drains and contain the leak using absorbent materials (sand or earth). Neutralization
: Often requires a specific deactivation solution (like sodium bisulfite) before disposal; consult the specific SDS for the manufacturer's recommended neutralizing agent.
: Always verify the specific revision date of your SDS, as formulations and regulatory requirements may change over time. of this SDS or information on compatible pumping equipment for corrosive biocides?
Introduction
Nalco 2593 is a chemical product widely used in various industries, including water treatment, oil and gas, and mining. As with any chemical substance, it is essential to handle Nalco 2593 with care and follow proper safety protocols to prevent adverse effects on human health and the environment. The Material Safety Data Sheet (MSDS) for Nalco 2593 provides critical information on the safe handling, use, storage, and disposal of this chemical product. This essay will review the MSDS for Nalco 2593, highlighting its composition, hazards, safety precautions, and emergency response procedures.
Composition and Physical Properties
According to the MSDS, Nalco 2593 is a liquid chemical product with a pH range of 2.5-4.5. Its active ingredient is a proprietary blend of polymers and surfactants. The product is supplied as a concentrated liquid, with a specific gravity of approximately 1.05-1.15. The MSDS also lists the following physical properties:
Hazards Identification
The MSDS for Nalco 2593 identifies several potential hazards associated with handling this chemical product. These include:
Safety Precautions
To ensure safe handling of Nalco 2593, the MSDS recommends the following precautions:
Emergency Response Procedures
The MSDS for Nalco 2593 provides guidance on emergency response procedures in case of spills, leaks, or other incidents:
Conclusion
The MSDS for Nalco 2593 provides essential information on the safe handling, use, storage, and disposal of this chemical product. By understanding the composition, hazards, and safety precautions outlined in the MSDS, users can minimize risks to human health and the environment. It is crucial to follow the recommended safety protocols and emergency response procedures to prevent accidents and ensure a safe working environment. Additionally, users should consult the manufacturer's instructions and local regulations for specific guidance on handling Nalco 2593.