Autodata Runtime Error 217 At 00580d29

Runtime errors frequently stem from missing or corrupt C++ redistributables. Even though Autodata is Delphi-based, it uses Windows system DLLs that depend on these.

Steps:

No — this is too specific and low‑level for academic publication.
If you meant a technical note or knowledge base article, you would need to contact AutoData Systems (now part of MTS – MTS Systems Corporation) or check their legacy support forums.

If you have a stack trace or a map file from the exact AutoData version, I can help pinpoint the exact routine at 00580d29. Otherwise, the practical path is to rule out environment corruption first.

Runtime error 217 at address in Autodata (specifically version 3.45) is a common failure typically triggered by incorrectly registered system files, missing background drivers like the Sentinel Key, or corrupted installation packages. Primary Troubleshooting Steps

Run as Administrator: Right-click the Autodata shortcut and select Run as Administrator. If this doesn't work, browse to the installation folder and run the install-32.exe or install-64.exe (matching your system) as an administrator to ensure all components are properly registered. autodata runtime error 217 at 00580d29

Manually Register DLL Files: One specific fix involves manually registering the ChilkatCrypt2.dll file. Open the Command Prompt as an administrator. Navigate to your Autodata folder (e.g., cd c:\adcda2). Type regsvr32 ChilkatCrypt2.dll and press Enter.

Repair Microsoft Visual C++ Redistributable: Corrupted runtime libraries are a frequent cause.

Go to Settings > Apps > Installed apps (or use the Control Panel).

Find the Microsoft Visual C++ Redistributable entries, select Change, then Repair.

Run System Repairs: Use built-in Windows tools to fix underlying OS corruption. Runtime errors frequently stem from missing or corrupt

In an elevated Command Prompt, run sfc /scannow and wait for it to finish. Follow up with DISM /Online /Cleanup-Image /RestoreHealth. Advanced Solutions

The "Autodata runtime error 217 at 00580d29" is intimidating, but it is rarely a sign of permanent data loss or a fatal system error. In 9 out of 10 cases, changing the default printer or running the program as an administrator in compatibility mode solves the problem instantly.

If you are a workshop owner, consider keeping a dedicated older PC (Windows 7) offline for legacy diagnostic software like older Autodata versions. Newer operating systems frequently break backward compatibility.

Summary checklist:

Have a fix that worked for you that isn’t listed here? Share it in the comments to help fellow technicians! Have a fix that worked for you that isn’t listed here

Based on user reports and technical bulletins, this particular error (217 at 00580d29) usually appears in the following scenarios:

Unlike a standard Windows crash, "Runtime Error 217" is a specific exception thrown by Borland Delphi (the programming language in which older versions of Autodata are written). Error 217 generally indicates an unhandled exception — meaning the software tried to perform an operation that the operating system deemed illegal or impossible.

More precisely, Error 217 often points to:

The specific hexadecimal address 00580d29 suggests the error is occurring during the initialization of a particular graphical component or database driver within Autodata.

Sohbeti Aç !
Merhaba , nasıl yardımcı olabiliriz ?
Sketchup Türkiye Ekibi
Merhaba
Yardımcı olabileceğimiz konu nedir ?