Anycubic Chiron Firmware 135 Download Repack Page
The stock 1.3.5 firmware has three famous problems:
A “repack” usually means someone has compiled a custom version of Marlin that:
If you're looking to repack the firmware, you're likely trying to customize it or ensure compatibility with certain modifications.
If you own an Anycubic Chiron, you know it’s a beast of a 3D printer. With its massive 400x400x450mm build volume, it promises big prints. However, many users have struggled with the stock user interface, thermal runaway protections, and quirky bed-leveling sensors.
This is where Firmware 1.3.5—specifically the community-repacked version—comes into play. Searching for the "Anycubic Chiron firmware 135 download repack" has become a rite of passage for Chiron owners looking to transform their printer from a temperamental giant into a reliable workhorse.
In this article, we will break down what firmware 1.3.5 is, why the "repack" matters, where to find it safely, how to install it, and the critical improvements you can expect.
When dealing with firmware updates or modifications, it's crucial to proceed with caution and ensure you're working with compatible and safe versions. If you're unsure, seeking advice from Anycubic support or the 3D printing community can provide clarity and help avoid potential issues.
Finding the Anycubic Chiron firmware 1.3.5 repack download is essential for owners of newer Chiron units who need to restore their machine's functionality after a failed update. Unlike the older v1.3.0 firmware typically found on official Western support pages, version 1.3.5 is required for printers equipped with the newer blue/yellow theme TFT panels. Why You Need Firmware 1.3.5 anycubic chiron firmware 135 download repack
The Anycubic Chiron was released with two distinct hardware revisions:
Version 1.3.0: Found on older machines with white/blue screen themes.
Version 1.3.5: Required for newer machines with blue/yellow screen themes.
Using the wrong version can break essential features like auto-leveling or even render the touch screen completely unresponsive. Many users unknowingly downgrade their machines when using Cura’s built-in firmware update tool, which often defaults to the older 1.3.0 version. Download Links
Because version 1.3.5 is often missing from the standard Anycubic Firmware & Software page, users have turned to community-shared mirrors and the original Chinese support site:
Official Source (CN Site): The most reliable source is the Anycubic Chinese Support Page (select Chiron from the menu).
Direct Download: Users on GitHub have shared a direct link to the v1.3.5 ZIP Archive. The stock 1
Community Mirror: A backup can often be found on Google Drive mirrors shared by users in 3D printing forums. How to Install the Repack
Preparation: Download the .hex file (motherboard firmware) and the .bin file (screen firmware). Motherboard Update: Connect your printer to a PC via USB. Open Ultimaker Cura or another slicer.
Go to Manage Printers -> Update Firmware -> Upload Custom Firmware and select the .hex file. Screen Update (Caution):
WARNING: Only update the screen if your display is broken or unresponsive. Many users report that flashing the screen with the .bin file included in some 1.3.5 packs can permanently freeze the display.
If necessary, place the .bin file on a formatted SD card, insert it into the slot behind the screen, and power on the machine. Alternative: Custom Marlin Firmware
If you are looking for more features like Thermal Runaway Protection, S-Curve Acceleration, or Manual Mesh Bed Leveling, many community members recommend switching to a custom Marlin repack rather than the stock 1.3.5 version. Popular options include:
Latest chiron ships with 1.3.5 firmware. Please provide source A “repack” usually means someone has compiled a
orangeworx commented. orangeworx. on Nov 18, 2022 · edited by orangeworx. Firmware 1.3.5 You can get it here: https://cn.anycubic.
Cause: Baud rate mismatch between motherboard and LCD.
Fix: Re-flash the motherboard using 250000 baud rate. Then re-flash LCD. If still failing, your repack may be for a different Trigorilla board version. Use M115 in a terminal to check your board revision.
The Anycubic Chiron is a large-format FDM 3D printer (400×400×450 mm). The stock firmware shipped with early models was often v1.3.0 or v1.3.5. While v1.3.5 is the last official release from Anycubic, it still contains bugs (e.g., inconsistent auto-leveling, thermal runaway protection not fully reliable, poor TFT responsiveness). Consequently, the community has created “repacks” — modified versions of v1.3.5 that fix bugs, enable safety features, and improve usability.
Important: Anycubic no longer hosts v1.3.5 on its official site. The most reliable source is community repositories (GitHub, Thingiverse, etc.).
After flashing both components:
Some users modify firmware to:
These modified firmwares are often shared on forums like:
But they are NOT official "repacks" – they are custom compilations.